The Megger technical library provides access to a range of additional content and resources such as technical guides, application notes and more. Use the filters to browse specific content (e.g. application notes) or refine your search to a particular electrical application area.
If you would like to see the content we have available on a particular subject or need to locate some software, simply enter a search below. Please note, you will need to create an account to access some resources.
Case study: What is melting here? Time for an SFRA test
This case study has been generously supplied by the Hitachi Energy Service group in Sweden. A 22 MVA, 10.5 kV/276 V (voltage regulation from 336 to 216 V), Diii furnace transformer, operating in heavy use for many years at a steel melting plant in Europe was subjected to a complete series of tests after a sudden failure during operation. The service contractor evaluated the electrical and dielectric condition of this transformer. During service, this type of transformer has its secondary winding connected externally in a Delta configuration through a high current bridge.
Published: 17 March 2022
Download PDF
Case study: True dynamic resistance measurement
Pinpointing concealed problems inside a resistive-type OLTC before physical inspection - the application of true DRM.A maintenance team at the Electric Power Transmission Network in the City of Karbala performed routine electrical tests on a transformer including: winding resistance measurements (WRM), transformer turns ratio (TTR), short circuit impedance (SCI), excitation current, and line-frequency power factor (a.k.a. dissipation factor or tan delta). This case study looks into their investigations and their results.
Published: 15 June 2021
Download PDF
Case study: BSES Rajdhani Power India
Electrical maintenance departments are often faced with the challenge of performing different tests on instrument transformers according to official standards and within a limited shutdown time. This is made even more difficult when multiple instruments are needed to perform all the required tests.
Published: 7 April 2021
Download PDF
Case study: NB DFR on HV CVTs
Reducing the risk of failure on high voltage instrument transformers in the transmission system using the application of narrowband dielectric frequency response (NB DFR) on HV CVTs.
Published: 10 March 2021
Download PDF
Case Study on IDAX300 and VAX020
The Power Grid Corporation of India Limited (PGCIL) is an Indian state-owned company headquartered in Gurugram (North India) engaged mainly in Trans-mission of Power and transmits about 50% of the total power generated in India on its transmission network. The company owns and operates about 1,61,790 circuit kms of transmission lines at 800/765 kV, 400 kV, 220 kV & 132 kV EHVAC and +500 kV HVDC levels and 248 sub-stations. Also, it has the transformation capacity of about 396 825 MVA as of 30th November 2019.
Published: 26 August 2020
Download PDF