Technical documents for the MPQ1000

Filter by application type:
    Showing item(s) 1 - 10 of 10 in total
35829 CT Adapter
The Megger 35829 CT Adapter is designed to allow the MPQ analyzers operate with various manufacturers current clamps. This CT allows current clamps that have male banana jack terminations to be used with the MPQ analyzer.
Published: 6 November 2019
Download PDF
Motor Analysis with the MPQ Analyser
Bearing failures are often blamed on poor lubrication. However, there are many other causes of bearing failures. Analysing the failure cause can lead to higher motor reliability.
Published: 8 September 2019
Download PDF
Pumping Station Motor Analysis
This test was performed at a pumping station that was using multiple 600HP motors and a VFD drive. The reported problem was the plant was not receiving adequate power output from the motors during peak times. It was not possible to connect to the inputs of the motors themselves so an MPQ2000 was connected to the output of the VFD and the following measurements were recorded.
Published: 7 December 2018
Download PDF
MPQ1000 Common Connections
An application note locoking at the common connections of the MPQ1000.
Published: 7 December 2018
Download PDF
Rapid Voltage Change (RVC)
A rapid voltage change is a fast rise or fall of the RMS voltage. This can be caused by the switching on of a specific load or by a sudden change in source voltage. Sudden source voltage changes can occur in solar grids when the sun is obscured by clouds. Source voltage changes can also occur in wind farms when then wind speed decreases. Load switching can cause a rapid voltage change if the rating of the load is a significant fraction of the fault level of the supply voltage.
Published: 7 December 2018
Download PDF
Mains Signalling
Power-line communication (PLC) carries data on a conductor that is also used simultaneously for AC electric power transmission or electric power distribution to consumers. It is also known as power-line carrier, power-line digital subscriber line (PDSL), mains communication, power-line telecommunications, or power-line networking (PLN).
Published: 6 December 2018
Download PDF
Solar Energy - Part 2 of 3: Programming a PQ Analyser
When examining potential power quality issues associated with solar panels, your power quality analyser should be programmed to examine a variety of different parameters outlined in this application note.
Published: 3 July 2018
Download PDF
Class A recording
This paper discusses what it means to have a Class A power quality analyser.
Published: 5 October 2017
Download PDF
PQ influences on telecommunications
When equipment trips offline, telecom customers can lose their service, costing the telecom money every minute the equipment is offline. This paper looks into how power quality testing can prevent this from happening.
Published: 21 February 2017
Download PDF
Approved SD Cards for the MPQ Series
Different brands and types of SD Cards have different characteristics. This paper shows the recommended types to use with the MPQ series.
Published: 21 February 2017
Download PDF